Skip to content
Intelligent SimulationPrimeRadiant EMEvaluate EM

PrimeRadiant EM · Sovereign physical intelligence · Available now

Electromagnetic intelligence.From fields to decisions.

See how source changes affect fields, RF performance, power, and losses. EM runs native Maxwell physics on Terminus Station and carries analytical sensitivities and Touchstone exports into your existing RF workflow—without a learned forward model.

For RF and microwave engineers, electromagnetic simulation teams, and scientific software developers.

Electromagnetic engineering · Local execution · Deterministic · Air-gap capable

Results for your engineering decisions

Connect field behavior to RF performance.

Understand what changes when you change the source. Inspect the field, quantify the network response, locate losses, and carry analytical sensitivities into the next engineering decision.

01

RF performance and impedance

Inspect S/Z/Y parameters, insertion and return loss, phase, group delay, VSWR, and normalized impedance or admittance.

02

Power flow, losses, and hotspots

Probe electric and magnetic fields at chosen coordinates. Examine energy, separated losses, source power, and deterministic hotspots.

03

Analytical response sensitivities

Evaluate how source changes affect fields and network response, retaining derivative and independent replay evidence.

04

Engineering-ready RF exports

Carry reverified results into existing tools through Touchstone 2.0 and CSV, preserving port order, units, reference impedance, and source lineage.

Benchmarks and test conditions September 2026
0110,000

Field locations

Query electric and magnetic fields at arbitrary coordinates.

027.118 ms

Field query + result check

10,000 field probes with independent verification.

034.282 ms

Network response + result check

75-ohm network response with independent verification.

043.650 ms

Network sensitivity + replay

Analytical network derivatives with an independent consistency check.

Field-query and RF network timings include result verification. Source solving is measured separately.

What you can do today

Resolve the field. Quantify the response. Reuse the result.

Connect your source configuration, field probes, and network ports. Calculate the field and RF response, inspect how they change with the source, and export the result with its units, port definitions, and replay evidence.

Explore the supported workflows
  1. 01

    Inspect complex fields

    Query electric and magnetic fields, Poynting flow, and arbitrary-coordinate probes.

  2. 02

    Evaluate the network

    Inspect port voltage and current, S/Z/Y parameters, insertion and return loss, phase, group delay, and VSWR within the applicable model.

  3. 03

    Vary the source

    Evaluate impressed-source response and analytical sensitivities with independent replay.

  4. 04

    Review the engineering effect

    Examine energy, losses, power, Maxwell stress, force, torque, margins, and field hotspots.

  5. 05

    Export into the RF workflow

    Deliver Touchstone 2.0 and CSV network results with port order, units, reference impedances, and source lineage preserved.

Compare the architecture and technical ecosystem

Where the product fits

Scientific models become operating infrastructure.

PrimeRadiants connects native scientific models to sovereign operational decisions. Fusion is the first commercial market; the same PRX architecture spans orbital systems, quantum hardware, electromagnetics, materials, and hypersonics.

Compare the execution models
Scientific execution, training, custody, and the path to action
CapabilityCAE / HPC physicsLearned physics modelsConventional controlPrimeRadiants PRX
Scientific basisNumerical physics solversTrained model, often with physics constraintsControl laws and plant modelsNative scientific execution
Time to actionWorkload and solver dependentFast inference after trainingReal-time control loopsNear-real-time qualified decision transactions
Training requirementNo model training requiredModel training or fine-tuningUsually no model trainingNo training required
Required inputsGeometry, conditions, material models, calibrationTraining inputs, validation, operating inputsTelemetry, setpoints, plant parametersAuthoritative inputs required by the physics transaction
Data custodyLocal, HPC, cloud, or hybridLocal, edge, or cloud; model pipeline dependentTypically on-device or localCustomer-controlled, air-gapped, no-egress capable
DesignEngineering analysis and optimizationPrediction and optimization within model coverageControl-system design and tuningIntegrated scientific design workflows
OperationsSimulation and external operational integrationsInference integrated into operating workflowsMonitoring and regulation of the target systemIntegrated physics-to-decision workflows
Physical controlController integration or co-simulationController integration and assuranceCore functionBounded, physics-aware, fail-closed control
ReplaySolver and saved-state dependentModel, version, and inputs dependentModel and control-log dependentSource-bound independent replay
EvidenceSolver outputs and workflow recordsModel, dataset, and experiment recordsTelemetry and event logsNative transaction evidence and provenance
DeploymentWorkstation, cluster, cloud, or HPCGPU workstation, server, cloud, or edgeDesktop, embedded, or industrial hardwareTerminus Station appliance
Across domainsSolver and product-suite dependentModel training or adaptation by domainPlant- and application-specificOne reusable PRX architecture across physical domains

Explore the approaches: CAE / HPCLearned physicsReal-time control

Technical ecosystem references

EM packages field response, RF network quantities, and analytical source sensitivities in an embeddable GPU SDK. Carry the calculation and its independent checks into your engineering environment.

Ansys HFSS

Full-wave 3D electromagnetic analysis with adaptive meshing, system workflows, and automation.

Our focus

Embed field queries, network response, and analytical sensitivities with independently replayable output.

Read Ansys HFSS documentation

CST Studio Suite

Time-domain, frequency-domain, integral-equation, and other solvers with hybrid and cross-verification workflows.

Our focus

Integrate the delivered field and network operations through a precompiled SDK and retain their result records.

Read CST Studio Suite documentation

COMSOL RF Module

RF and multiphysics analysis with ports, S-parameters, and network representations.

Our focus

Connect field and source analysis to portable Touchstone 2.0 and CSV results with the engineering context intact.

Read COMSOL RF Module documentation

Built for your engineering team

Your workflow. Results with receipts.

Run EM on Terminus Station and connect it to your RF tools through the supplied SDK. The evaluation includes native integration interfaces, reference cases, independent replay, and Touchstone 2.0 and CSV exports.

Cryptographic proof pack

RF results ready for the next tool.

SHA-256Immutable identityContent-addressed evidence

Inspect fields, network response, and source sensitivities together. Carry the result into your RF tools with port definitions, units, and independent replay intact.

Traceable inputs
Sources, field probes, ports, reference impedances
Explainable results
RF response, field behavior, source sensitivities
Independent checks
Numerical replay and consistency identities
Proof-pack anatomy · Traceable. Explainable. Replayable.
Explore the evidence: One RF result. Ready for the next tool.

Inside the RF proof pack

Inspect field response and network performance together. Keep source sensitivities, units, port definitions, and independent checks attached as results move into your RF analysis workflow.

7.118 ms

Field query + verification

10,000 field probes in the reference case.

4.282 ms

RF network + verification

75-ohm network response with independent checks.

1.163 × 10⁻¹⁴

Source adjoint residual

Numerical consistency of the analytical source derivatives.

5.178 × 10⁻¹⁶

Field scaling error

Amplitude-scaling identity in the reference case.

Independent integrity checks

Independent numerical replay checks field and source relationships. Installation validates the supplied archive digest before publishing the destination.

Verify and reuse the saved result

Reopen immutable result components through the native replay consumer. Carry Touchstone and CSV outputs into RF tools with port order, units, and source traceability intact.

Field-query and RF network timings include result verification.

Work with us

Put native electromagnetics inside your tools.

Bring your source configuration, field-query or RF-network workflow, and the performance quantities your engineering team needs to evaluate.

Evaluate EM